Post Offer Free
Chongqing Gold M&E Equipment Co.,Ltd.  

Gold Index: 13019

You are here: home  > Electrical Tester  > Gold Company CT PT Analyzer

Gold Company CT PT Analyzer 

Price: 1.0~10.0 USD 
Payment Terms: T/T,L/C,WU 
Place of Origin: Chongqing, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: GDVA-404
Production Capacity: 100pcs/month
Delivery Date: 10 business days
Test Standard: IEC60044
Means of Transport: Ocean,Land,Air
Packing: Wooden Case
Brand Name: Gold

1)Excitation curve and parameters test
2)Turns ratio test
3)Ratio and phase error test
4)Polarity mark check
5)Coil resistance measurement

Tests for Current Transformer:


1)Excitation curve and parameters test
2)Turns ratio test
3)Ratio and phase error test
4)Polarity mark check
5)Coil resistance measurement
6)Secondary loop burden measurement
7)Error line curve test for protection CT
8)Transient CT parameters test
9)CT nameplate guess
10)Saturation hysteresis loop curve measurement

Tests for Voltage Transformer:


1)Turns ratio test and phase angle error test
2)Polarity test
3) Secondary burden test
4) Coil resistance test

Applications for CT PT Tester:


1) CT nameplate check
2) CT parameters check in work burden
3) CT transient parameters analysis
4) CT ratio and phase error calibration
5) PT routine test

CT PT Analyzer Technical Index:


1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply: AC220V±10%,50Hz/60Hz±10%
3 Power output: 0.1~180V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output:300VA
6 Maximum knee voltage measurement:45kv
7 Current measurement: 
  Range:0~10A (automatically change range in 0.1/0.4/2/10A) 
  Error <±0.1%+0.01%FS
8 Voltage measurement:
  Range:0~200 V (automatically change range in 1V/10V/70V/200V)
  Error < ±0.1%+0.01%FS
9 Turns ratio measurement:
  Range :1~35000,
  1~2000 error<0.05%
  2000~5000 error>0.1%
  5000~35000 error<0.2%
10 Phase measurement: error:±2min,resolution:0.01min
11 Coil resistance measurement: 
  Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
  Error< 0.2%RDG+0.02%FS
  Maximum resolution:0.1mΩ
12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree
13 CT Secondary burden: 
  Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
  Error <0.2%RDG+0.02%FS 
  Maximum resolution 0.001ohm
14 PT Secondary burden: 
  Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
  Error <0.2%RDG+0.02%FS 
  Maximum resolution: 0.1ohm
15 PT ratio measurement: 
  Range :1~35000,
  1~5000 error<0.2%
  5000~35000 error<0.5%
16 Saved data groups:>1000groups
17 Work condition: Temperature:-10℃~50℃, moist:≤90%
18 Size: 485mm×356mm×183mm
19 Weight: <15Kg


bigPhoto
 Ms. Daisy Tao

Tel: 86-23-62984892
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Related Products

Company Info

Chongqing Gold M&E Equipment Co.,Ltd. [China (Mainland)]


Business Type:Manufacturer
City: Chongqing
Province/State: Chongqing
Country/Region: China (Mainland)

You May Like:

Product (204)